<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: Port v2 Sensor
The Port v2 sensor monitors a network service by connecting to one or more of its TCP/IP ports.
Depending on your settings, the sensor can alert you either when the monitored port is open or when it is closed.
This sensor is in beta status. The operating methods and the available settings are still subject to change. Do not expect that all functions work properly, or that this sensor works as expected at all.
Port v2 Sensor
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
Dutch: Port v2
French: Port v2
German: Port v2
Japanese: ポート v2
Portuguese: Porta v2
Russian: Порт v2
Simplified Chinese: Port v2
Spanish: Puerto v2
Remarks
This sensor requires that the Beta Sensors experimental feature is enabled.
This sensor supports IPv6.
This sensor has a very low performance impact.
Known Issues
The sensor shows the Unknown status if a sensor scan was executed during the scan of the
If this issue occurs, reduce the list of monitored ports or increase the Scanning Interval of the sensor. The scan of each port takes about two seconds. For example, if you monitor the ports 1-900, the sensor needs around 1,800 seconds (30 minutes) to complete the port list.
Detailed Requirements
Requirement
Description
Enabled Beta Sensors experimental feature
This sensor requires that the Beta Sensorsexperimental feature of PRTG is enabled.
If the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?
This setting is for your information only. You cannot change it.
Tags
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
tcp
portsensor
portrangesensor
Priority
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority () to the highest priority ().
Port Specific
Port Specific
Setting
Description
Timeout (Sec.)
Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 900 seconds (15 minutes).
If the reply takes longer than this value, the sensor cancels the request and shows a corresponding error message.
Port-by-Port Delay (ms)
Define how long the sensor waits before it tries to connect to the next port. The maximum delay value is 100 ms.
Port List
Enter the port numbers that the sensor tries to connect to. Each port number must have its own line. PRTG supports the port numbers 1 - 65535. You can also specify port ranges by using A-B, for example 8080-8090. Enter an integer.
Sensor Display
Sensor Display
Setting
Description
Primary Channel
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
Graph Type
Define how different channels are shown for this sensor:
Show channels independently (default): Show a graph for each channel.
Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic. You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
Stack Unit
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
This sensor has a fixed minimum scanning interval for performance reasons. You cannot use a shorter scanning interval. Consequently, shorter scanning intervals in the Monitoring settings are not available for this sensor.
The minimum scanning interval of this sensor is 1 minute.
The recommended scanning interval of this sensor is 5 minutes.
Scanning Interval
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Schedules, Dependencies, and Maintenance Window
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.
Access Rights
Access Rights
For more information, see section Root Group Settings, section Access Rights.
Channel List
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel
Description
Closed Ports
The number of closed ports
Downtime
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status
Errors
The number of errors
This channel has a default limit
Upper error limit: 0
Maximum Connect Time
The maximum time until a request to connect to a port was accepted